logo
Steps to Take To Perfectly Maintain the Condensing Units

Maintaining condensing units includes a wide range of aspects since you have a progression of parts to check and clean. Each specialist will have its functioning strategies in the field. However, a few hints and proposals are always welcoming. Thus, here are a few helpful tips to maintain the condensing unit.  


Preventive maintenance

The absence of preventive maintenance and cleaning can make the compressor overheat. It can reach a state where it requests such a lot of electric flow that the OVL goes into activity, switching off the compressor, before it arrives at the objective temperature, to shield the engine from burning.



If this begins to happen often, the primary parts to quit working are the electrical parts. That is because these parts have a life expectancy in light of the number of cycles they will make. If they go into cycles at regular intervals, when it should be not so frequent, they will before long begin coming up short until they burn. Most issues in the field are because of electrical parts disappointments and not simply the compressor.


How to decide when there might be air in the condenser


High head pressure in a generally typically working framework can show air or non-condensable in a framework. To check for an obstructed drier, take the pressure drop across the drier. It should be something like 2 PSIG, assuming the drier has pressure ports. Additionally utilize a 5-second acid test pack to decide whether there is abundance air, dampness or acid in a framework. If you find any of those, the refrigerant charge should require removal and re-energized after a decent vacuum.


Determining how unsoiled the condenser truly is


Whenever you have a messy condenser, the exchange of heat with the encompassing can be compromised until the refrigerant gas doesn't transform into a fluid. Typically, you will understand the condenser is not spotless by the indications introduced by the compressor or the application, for example, loss of performance and absence of sub cooling.


One manifestation is the point at which the application's HPCO goes into activity, switching off the compressor before arriving at the set point temperature. Another comparable side effect is if the compressor's over-burden defender activates, likewise switching off the compressor before arriving at set point temperature. In this way, the blower performs frequently on and off cycles without getting the application to the ideal temperature.



In this way, if you notice high pressure, feel free to clean the condenser coil with water and review. For this situation, a coil cleaning is to be done first. If the water flushing fixes the issue, feel free to have chemical cleaning. After cleaning coils, super heat and sub cooling can be utilized to be certain the coils are spotless and running productively. Additionally, you can check if the draw down and defrost routine occurs as indicated by the hardware maker's determinations.


After having the best condensing units from Africhill, if you follow these maintenance tips the unit will last long. They have the expertise to manufacture the best units according to your requirements. Reach them at +27 (0) 11 396 2402 to place your order. 



0 Comments

Please login to post your comment..

Quick Contact
Reviews
  • Be the first one to review us.

Post your Review

Rate it